descriptionWork Description18kw PV roof install / 40 panels; ess (2); mpr; trenching required:ac wire to be trenched •length of trench - 13'•depth of trench - 22â€â€¢material we are trenching through - dirt; meter bypas level meter base.
descriptionWork Description12.3 kW PV roof install / 30 panels with ess; upgrade service feeder to 150 rated.• meter can replacement: existing meter can to be replaced with new meter can; meter bypass levelmeter base per plans.
descriptionWork Description19.27 PV roof install / 47 panels with (2) ess per plans; meter enclosure replacement: meter enclosure relocation meter is undersized and too close to a/c unit, new ameren approved 200 amp millbank meter main combo • main panel replacement: existing 100 amp main panel with 100 amp main breaker to be replaced with new 200 amp main panel with 200 amp main breaker; meter bypasslevel meter base.
descriptionWork Description19.27kw PV roof install; 47 panels; ess; service entrance conductors to be replaced; main panel replacement; meter enclosure and meter bypass level meter base
descriptionWork Description18.04kw PV roof install / 44 panels with ess; • service conductor reefed to be replaced• new 200a meter enclosure to be installed; meter bypass level meter base per plans.
descriptionWork Description8.91kw PV roof install / 22 panels with ess; mpu and meter bypass level per plans
descriptionWork Description10.25kw PV roof install / 25 panels wiht ess; mpu; span sub panel; meter enclosure replacement and meter bypass level meter base per plans.
descriptionWork Description9.84kw PV roof install / 24 panels with ess; meter can replacement; with meter bypass level meter base per plans.
descriptionWork DescriptionInstall residential roof solar panels.
descriptionWork Description• system size: 6.15kw dc, 5.76kw ac• modules: (15) hanwha q-cells: q.peak duo blkml-g10+ 410• inverters: (1) solaredge technologies:se5700h-usmn• optimizers: (15) solaredge technologies: u650• energy storage system: (1) franklin: apower xyyy15kwh, 10kw inverter output, lithium ironphosphate battery (weight: 357lb each)• microgrid interconnect device: (1) 280a agate xcontrol panel• racking: alphatrack to framing - snr-dc-00370• de-energize lines for install, meter intercept forameren utilit• new meter enclosure
descriptionWork DescriptionInstall residential roof solar panels.
descriptionWork DescriptionInstall residential roof solar panels w/added sow:meter enclosure: replace existing meter with newameren approved 200a/100a meter/main panel withlever bypass.
descriptionWork DescriptionInstall residential roof solar panels w/added sow:• sub panel relocation: relocation of the mainelectrical panel required for workingclearance and/or code compliance.• meter can replacement: existing meter can to bereplaced with new meter can.• service entrance conductors to be replaced.• structural upgrades required on ar-01, & ar-02.see detail.
descriptionWork DescriptionInstall solar panels on detached structure.
descriptionWork DescriptionInstall residential roof solar panels.
descriptionWork DescriptionInstall residential roof solar panels.
descriptionWork DescriptionInstall residential roof solar panels and on detached structure.
descriptionWork DescriptionInstall residential roof solar panels.
descriptionWork DescriptionInstall residential roof solar panels.
descriptionWork DescriptionInstallation of residential roof mounted solar panels w/ added SOW: Main Panel Relocation required due to panel partially covered by the ceiling.
descriptionWork DescriptionInstall residential roof solar panels w/added sow:•meter enclosure
descriptionWork DescriptionInstall residential roof solar panels.
descriptionWork DescriptionInstall resdential roof solar panels.
descriptionWork DescriptionInstallation of Residential Roof Mounted Solar Panels w/ Added SOW: •NEW 200A MILBANK METER MAIN• TRENCHING REQUIRED• TRENCHING REQUIRED,DC WIRE TO BE TRENCHED:51 FT AND 18" DEEP IN DIRT AND GRAVEL
descriptionWork DescriptionInstallation of residential roof mounted solar panels w/ added SOW: METER CAN REPLACEMENT: EXISTING METER CAN TO BEREPLACED WITH NEW METER CAN.MAIN PANEL REPLACEMENT: EXISTING 150 AMP MAINPANEL WITH 150 AMP MAIN BREAKER TO BE REPLACED WITHNEW 200 AMP MAIN PANEL WITH 200 AMP MAIN BREAKER
descriptionWork DescriptionInstallation of Residential Roof Mounted Solar Panels w Added SOW: TRENCHING REQUIREDDC WIRE TO BE TRENCHED 12 FT : 3FT CONCRETEMATERIAL.DC WIRE TO BE TRENCHED 18" DEPTH .• MINIMUM TRENCH DEPTH: 6"• ADD NEW 225AMP MAIN PANEL WITH NEW 200AMP MAINBREAKER TO BE INSTALLED
descriptionWork DescriptionInstallation of Residential Roof Mounted Solar Panels w/ Added SOW: MAIN PANEL REPLACEMENT: EXISTING 200 AMP MAIN PANELWITH 200 AMP MAIN BREAKER TO BE REPLACED WITH NEW200 AMP MAIN PANEL WITH 200 AMP MAIN BREAKER
descriptionWork DescriptionInsta;llation of rwesidential roof mounted solar panels.NEW 100A/100A NON BACKUP PANEL TO BE INSTALLED
descriptionWork DescriptionInstallation of residential roof mounted solar panels
descriptionWork DescriptionInstallation of Residential Roof Mounted Solar Panels W/ Added Scope of Work: Meter Enclosure
descriptionWork DescriptionInstallation of residential roof mounted solar panels w/ added sow: main panel replacement: existing 100 amp mainpanel with 100 amp main breaker to be replaced withnew 225 amp main panel with 200 amp main breaker
descriptionWork DescriptionInstallation of residential roof mounted solar panels w/ added sow:service entrance conductors to be replaced.trenching required:dc wire to be trenched 7 ft in concrete and dirtmaterial .meter can replacement: existing meter can to bereplaced with new meter can.
descriptionWork DescriptionInstalltion of residential roof mounted solar panels
descriptionWork DescriptionInstallation of residential roof mounted solar panels w/ added sow: main panel replacement: existing 200 amp main panelwith 200 amp main breaker to be replaced with new225 amp main panel with 200 amp main breaker.service entrance conductors to be replacedtrenching required: ac wire to be trenched 85 ft indirt material
descriptionWork DescriptionInstallation of residential roof mounted solar panels w/ added sow: meter can replacement: existing meter can to bereplaced with new meter can.main panel replacement: existing 100 amp main panelwith 100 amp main breaker to be replaced with new125 amp main panel with 100 amp main breaker
descriptionWork DescriptionInstallation of residential roof mounted solar panels
descriptionWork DescriptionInstallation of residential roof mounted solar panels
descriptionWork DescriptionInstallation of residential solar panels w/ added scope of work: meter enclosure replacement: replace existingundersized meter with new ameren approved200a/100a meter/main panel with lever bypass.• trenching required: ac wire to be trenched 24 ft indirt material.
descriptionWork DescriptionInstallation of residential roof mounted solar panels.
descriptionWork DescriptionInstallation of residential solar panels
descriptionWork DescriptionInstallation of residential roof mounted solar panels.
descriptionWork DescriptionInstallation of residential solar panels w/ sow: meter can replacement: existing meter can to bereplaced with new meter can.
descriptionWork DescriptionInstallation of resdiential roof mounted solar panels w/ added sow: replace existing meter enclosure with a new 200aameren approved lever bypass meter/main panel
descriptionWork DescriptionInstallation of resdiential solar panels w sow: • sub panel replacement: existing 100 amp main subpanel with 100 amp sub main breaker to be replacedwith new 125 amp sub panel with 100 amp sub mainbreaker.• meter enclosure : install new 200a/100a amerenapproved lever bypass meter-main.• service entrance conductors to be replaced.• refeed line and load side from meter to weatherhead and meter to interior sp.
descriptionWork DescriptionInstallation of residential solar panels w/ added scope of work:• service entrance conductors to be replaced.• replace meter with new 200a/200 meter/main withlever bypass• replace or install new service mast &weatherhead• new 125a nbulp next to the main panel. Less than6ft
descriptionWork DescriptionInstallation of residential roof solar panels
descriptionWork DescriptionInstallation of residential solar panels w. Added scope of work: -sub panel replacement: existing 200 amp sub panelwith 200 amp sub breaker to be replaced with new200 amp sub panel with 200 amp sub breaker.-service entrance conductors to be replaced.-meter main combo replacement: newameren-approved 200a panel with new 200a mainbreaker.
descriptionWork DescriptionInstallation of residential solar panels
descriptionWork DescriptionInstallation of residential solar panels w/ added scope of work: meter adapter: install a new ameren approved200a/200a meter/main panel with lever bypass
descriptionWork DescriptionInstallation of residential solar panels
descriptionWork DescriptionInstallation of residential solar panels
descriptionWork DescriptionInstallation of residentila solar panels w/ added scope of work: meter can replacement: existing meter can to bereplaced with new 200a/150a meter-main panel.
descriptionWork DescriptionInstallation of residential roof solar panels
descriptionWork DescriptionInstallation of residential solar panels
descriptionWork DescriptionInstallation of resiential solar panels w/ added scope of work: meter can replacement: existing meter can to bereplaced with new meter can
descriptionWork DescriptionInstallation of residential solar panelsadded scope of work: meter main replacement: existing meter can to bereplaced with new ameren approved 200a/100ameter main enclosure
descriptionWork DescriptionInstallation of residential solar panelsadded scope of work- • meter main replacement: existing meter can to bereplaced with new approved 200a/100a meter mainenclosure.
descriptionWork DescriptionInstall residential roof solar panels w/adde sow:• meter/main replacement: existing meter canto be replaced with new 200a/100a amerenapproved meter-main enclosure.
descriptionWork DescriptionInstall residential roof solar panels.
descriptionWork DescriptionInstall residential roof solar panels.
descriptionWork DescriptionInstall residential roof solar panels.
descriptionWork DescriptionInstall residential roof solar panels.
descriptionWork DescriptionInstall residential roof solar panels w/added sow:• meter main combo replacement: newameren-approved 200a panel with new 200a mainbreaker.• service entrance conductors to be replaced.
descriptionWork DescriptionInstall residential roof solar panels w/added sow:install a new ameren approved meter with 200alever bypassspan panel installed as main panel.
descriptionWork DescriptionInstall residential roof solar panels w/added sow:• meter can replacement: existing meter can to bereplaced with new meter can.
descriptionWork DescriptionInstall residential roof solar panels.
descriptionWork DescriptionInstall residential roof solar panels
descriptionWork DescriptionInstall residential roof solar panels.
descriptionWork DescriptionInstall residential roof solar panels w/added scope of work:€¢ meter can replacement: existing meter can to bereplaced with new meter can.
descriptionWork DescriptionINSTALL RESIDENTIAL ROOF SOLAR PANELS W/ADDED SCOPE OF WORK: Span Panel Details: Replace MSP with Span panel Existing MSP: 100/100
descriptionWork DescriptionInstall residential rooftop solar panels
descriptionWork DescriptionInstallation of residential rooftop solar panels.
descriptionWork DescriptionInstallation of residential rooftop solar panels.
descriptionWork DescriptionInstallation of residential rooftop solar panels.
descriptionWork DescriptionInstallation of residential rooftop solar panels w/added scope of work:€¢ main panel is located with a tank and pipe in frontof it relocate main panel to the left, free from anyobstructions.