5025 E Stewart Dr, Decatur, IL 62521

Project TypeSolar
Permit Date2026-06-22Permit Value$28,388
OwnerNot specifiedApplicantPaul MarhoferContractorSpartanx
Work DescriptionInstallation of roof mount solar panels / upgrading the utility meter to a new Milbank U9551-RXL-QG-5T9-AMS lever-bypass meter socket per Ameren requirements, replacing the service line and load-side conductors, installing 2" RMC conduit/riser
View DetailsView MapSLR-26-125

2156 N Dennis Ave, Decatur, IL 62526

Project TypeSolar
Permit Date2026-06-22Permit Value$33,594
OwnerNot specifiedApplicantPaul MarhoferContractorSpartanx
Work DescriptionInstallation of roof mount solar panels / upgrading the utility meter with a new Milbank U9551-RXL-QG-5T9-AMS lever bypass meter socket, completing the required riser, service line, and load-side upgrades, installing a new 100A/100A Siemens E0202MB1100 main breaker enclosure below the utility meter, and refeeding the existing 100A/100A GE main service panel from the new MBE
View DetailsView MapSLR-26-124

131 Wisconsin Dr, Decatur, IL 62526

Project TypeElectrical
Permit Date2026-06-18Permit Value$5,000
OwnerNot specifiedApplicantPaul MarhoferContractorSpartanx
Work DescriptionElectrical scope of work includes relocating/upgrading the utility meter with a Milbank U9551-RXL-QG-5T9-AMS lever-bypass meter socket, installing 2" RMC conduit per Ameren requirements, ensuring service line height is minimum 12' and meter height is 54"-66".

2028 S Brownlow CT, Decatur, IL 62521

Project TypeSolar
Permit Date2026-06-16Permit Value$28,741
OwnerNot specifiedApplicantPaul MarhoferContractorSpartanx
Work DescriptionInstallation of roof mount solar panels ; Installing a new utility meter socket: Milbank U9551-RXL-QG-5T9-AMS. Adding a 30A PV breaker into the existing MSP. Adding a 30A non-fused AC disconnect. Relocating two existing 20A breakers. Correcting existing double taps by moving circuits to existing subpanel.
View DetailsView MapSLR-26-111

475 W Decatur St, Decatur, IL 62522

Project TypeSolar
Permit Date2025-12-02Permit ValueNot specified
OwnerNot specifiedApplicantPaul MarhoferContractorSpartanx
Work DescriptionInstall a 17.8 kW residential rooftop solar PV system (40 × 445W Canadian Solar modules with 40 Enphase IQ8HC microinverters) and 2 × Tesla Powerwall 3 batteries, including Unirac racking, 3/4" EMT/PVC with ~50 ft trench, AC disconnects, combiner, Backup Gateway 3, and related wiring. Scope includes full service upgrade: MMU at existing 200A Siemens MBE, new 200A/200A backup load panel, relocation of all loads to new BLP, and relocation of utility meter to exterior location.
View DetailsView MapSLR-25-338